无码av一区二区三区无码,在线观看老湿视频福利,日韩经典三级片,成 人色 网 站 欧美大片在线观看

歡迎光臨散文網(wǎng) 會(huì)員登陸 & 注冊(cè)

CheckCIF-PLAT141-150

2020-05-10 09:03 作者:DJ_Tokyo  | 我要投稿

PLAT141 Type_4 s.u. on a - axis small or missing

The s.u. on the a-axis is small or missing. The presence of s.u.'s (where required) and value are checked. S.u.'s as given by the diffractometer software are often much smaller then realistic.

a軸的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。檢查標(biāo)準(zhǔn)偏差(如需要)及其值。衍射儀軟件給出的標(biāo)準(zhǔn)偏差通常比實(shí)際小得多。

(http://journals.iucr.org/services/cif/checking/PLAT141.html)

警告原因:a軸的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。

解決策略:若缺失,則檢查是否還原過(guò)程某一步出問(wèn)題,可重新還原數(shù)據(jù)。若太小,則適當(dāng)增大其數(shù)值。

PLAT142 Type_4 s.u. on b - axis small or missing

The s.u. on the b-axis is small or missing. The presence of s.u.'s (where required) and value are checked. Su's as given by the diffractometer software are often much smaller then realistic.

b軸的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。檢查標(biāo)準(zhǔn)偏差(如需要)及其值。衍射儀軟件給出的標(biāo)準(zhǔn)偏差通常比實(shí)際小得多。

(http://journals.iucr.org/services/cif/checking/PLAT142.html)

警告原因:b軸的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。

解決策略:若缺失,則檢查是否還原過(guò)程某一步出問(wèn)題,可重新還原數(shù)據(jù)。若太小,則適當(dāng)增大其數(shù)值。

PLAT143 Type_4 s.u. on c - axis small or missing

The s.u. on the c-axis is small or missing. The presence of s.u.'s (where required) and value are checked. Su's as given by the diffractometer software are often much smaller then realistic.

c軸的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。檢查標(biāo)準(zhǔn)偏差(如需要)及其值。衍射儀軟件給出的標(biāo)準(zhǔn)偏差通常比實(shí)際小得多。

(http://journals.iucr.org/services/cif/checking/PLAT143.html)

警告原因:c軸的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。

解決策略:若缺失,則檢查是否還原過(guò)程某一步出問(wèn)題,可重新還原數(shù)據(jù)。若太小,則適當(dāng)增大其數(shù)值。

PLAT144 Type_4 s.u. on alpha small or missing

The s.u. on alpha is small or missing. The presence of s.u.'s (where required) and value are checked. Su's as given by the diffractometer software are often much smaller then realistic.

α角的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。檢查標(biāo)準(zhǔn)偏差(如需要)及其值。衍射儀軟件給出的標(biāo)準(zhǔn)偏差通常比實(shí)際小得多。

(http://journals.iucr.org/services/cif/checking/PLAT144.html)

警告原因:α角的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。

解決策略:若缺失,則檢查是否還原過(guò)程某一步出問(wèn)題,可重新還原數(shù)據(jù)。若太小,則適當(dāng)增大其數(shù)值。

PLAT145 Type_4 s.u. on beta small or missing

The s.u. on beta is small or missing. The presence of s.u.'s (where required) and value are checked. Su's as given by the diffractometer software are often much smaller then realistic.

β角的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。檢查標(biāo)準(zhǔn)偏差(如需要)及其值。衍射儀軟件給出的標(biāo)準(zhǔn)偏差通常比實(shí)際小得多。

(http://journals.iucr.org/services/cif/checking/PLAT145.html)

警告原因:β角的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。

解決策略:若缺失,則檢查是否還原過(guò)程某一步出問(wèn)題,可重新還原數(shù)據(jù)。若太小,則適當(dāng)增大其數(shù)值。

PLAT146 Type_4 s.u. on gamma small or missing

The s.u. on gamma is small or missing. The presence of s.u.'s (where required) and value are checked. Su's as given by the diffractometer software are often much smaller then realistic.

γ角的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。檢查標(biāo)準(zhǔn)偏差(如需要)及其值。衍射儀軟件給出的標(biāo)準(zhǔn)偏差通常比實(shí)際小得多。

(http://journals.iucr.org/services/cif/checking/PLAT146.html)

警告原因:γ角的標(biāo)準(zhǔn)偏差(s.u.)太小或缺失。

解決策略:若缺失,則檢查是否還原過(guò)程某一步出問(wèn)題,可重新還原數(shù)據(jù)。若太小,則適當(dāng)增大其數(shù)值。

PLAT147 Type_1 s.u. on symmetry restricted cell angle

There should be no s.u. on symmetry constrained cell angles.??

Example: No s.u. on alpha, beta and gamma for orthorhombic symmetry.

對(duì)稱(chēng)限制的晶胞角度不應(yīng)有標(biāo)準(zhǔn)偏差(s.u.)。

例如:對(duì)于正交對(duì)稱(chēng)來(lái)說(shuō),α、β和γ不存在標(biāo)準(zhǔn)偏差。

(http://journals.iucr.org/services/cif/checking/PLAT147.html)

警告原因:對(duì)稱(chēng)限制的晶胞角度不應(yīng)有標(biāo)準(zhǔn)偏差(s.u.),但數(shù)據(jù)給出了其標(biāo)準(zhǔn)偏差。

解決策略:將其標(biāo)準(zhǔn)偏差改為0即可。

PLAT148 Type_3 s.u. on a, b, or c - axis too large

The s.u. on the reported -axis is unexpectedly large.

所報(bào)告的晶軸的標(biāo)準(zhǔn)偏差(s.u.)出乎意料地大。

(http://journals.iucr.org/services/cif/checking/PLAT148.html)

例:PLAT148_ALERT_3_B su on the a - Axis is Too Large (x 1000) . 12 Ang.

PLAT148_ALERT_3_B su on the b - Axis is Too Large (x 1000) . 13 Ang.

PLAT148_ALERT_3_B su on the c - Axis is Too Large (x 1000) . 14 Ang.

警告原因:a、b、c軸誤差較大。

解決策略:檢查數(shù)值是否填錯(cuò),否則需給出合理解釋。對(duì)于這三個(gè)錯(cuò)誤主要是收錄晶體還原數(shù)據(jù)時(shí),最終的晶胞參數(shù)偏差太大造成的,最好重新收錄,實(shí)在要消除也可以,就是在ins文件中把偏差改小,詳見(jiàn)下面的例子:

TITL A in Pnma

CELL 0.71073 12.1750 8.9250 8.9372 90.000 90.000 90.000

ZERR 8.00 0.0014 0.0008 0.0009 0.000 0.000 0.000

LATT 1

SYMM 0.5-X, -Y, 0.5+Z

SYMM -X, 0.5+Y, -Z

SYMM 0.5+X, 0.5-Y, 0.5-Z

在ZERR后面的三個(gè)單包參數(shù)的下面對(duì)應(yīng)的偏差改到0.00**就可以了

PLAT149 Type_3 s.u. on alpha, beta or gamma too large

The s.u. on the reported angle is too large.

所報(bào)告的晶胞角度的標(biāo)準(zhǔn)偏差(s.u.)太大。

(http://journals.iucr.org/services/cif/checking/PLAT149.html)

警告原因:α、β、γ軸誤差較大。

解決策略:檢查數(shù)值是否填錯(cuò),否則需給出合理解釋。對(duì)于這三個(gè)錯(cuò)誤主要是收錄晶體還原數(shù)據(jù)時(shí),最終的晶胞參數(shù)偏差太大造成的,最好重新收錄,實(shí)在要消除也可以,就是在ins文件中把相應(yīng)偏差改小。

PLAT150 Type_1 Check Volume

An ALERT is issued when the reported unit cell volume differs significantly from the volume calculated on the basis of the supplied cell dimensions.

當(dāng)所報(bào)告的晶胞體積與基于所提供的晶胞尺寸所計(jì)算得到的晶胞體積明顯不同時(shí),發(fā)布此警告。

(http://journals.iucr.org/services/cif/checking/PLAT150.html)

警告原因:所報(bào)告的晶胞體積與基于所提供的晶胞尺寸所計(jì)算得到的晶胞體積明顯不同。

解決策略:檢查是否晶胞定錯(cuò),否則需要給出合理解釋。最好重新收錄數(shù)據(jù)。


CheckCIF-PLAT141-150的評(píng)論 (共 條)

分享到微博請(qǐng)遵守國(guó)家法律
改则县| 资中县| 石门县| 海阳市| 巴林右旗| 怀集县| 九龙坡区| 城市| 常德市| 重庆市| 砀山县| 陇川县| 奈曼旗| 金溪县| 昭通市| 吐鲁番市| 谷城县| 永德县| 子长县| 慈利县| 禄劝| 建平县| 六盘水市| 衢州市| 张家川| 泽普县| 白河县| 玉溪市| 连南| 武川县| 射洪县| 抚宁县| 冀州市| 马龙县| 高雄市| 海阳市| 亳州市| 马龙县| 平山县| 灵璧县| 旌德县|